Envoy Installation and Operation
2014 Enphase Energy Inc. 141-00011 Rev 05
50
NOTE: Do not click or select the box under the column labeled Select.
2. Click on the serial number of the unit showing the “DC Resistance Low - Power Off” condition.
The Control Flags screen appears.
CAUTION: The other control flags (reboot and cmd-alert) on this screen should be used only
when recommended by Enphase. Their functions are:
reboot - reboots the inverter
cmd-alert - clears a condition flag for a command sent
3. In the clear-dc-resistance-low box, select set.